Does it matter how high up the ACS A/A+ is mounted?
No! When the boat moves, roll and pitch angles will be the same regardless of placement.

How do I connect the ACS A/A+ to my Eltrim trim tabs?
Click on the icon below for a connection diagram:

 


 

Two indicator LED's are blinking
The current consumption of the valves controlling the trim tabs (only hydraulic trim tabs) is checked at calibration. Should it later on exceed the maximum, two indicator LED's start blinking. It may depend on:
1. Wrong connection of trim tabs
2. Shortcircuit in the trim tab valves


Four indicator LED's are blinking
If the control panel cannot communicate with the main unit, four indicator LED's will start blinking. Check the wiring!

How do I connect the ACS A/A+ to TFX trim tabs?
Teleflex uses a three wire cable between the control panel and the pump unit. Connect the three wires according to the colour codes in the user's manual and leave terminal 5 unconnected.